SRB 301LC/B

  • 3 safety contacts, STOP 0
  • 1 Signalling output
  • Fit for signal evaluation of outputs of safety magnetic switches (to this end, integrated current and voltage limiters)
  • Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
  • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains

SRB 301MC

  • 3 safety contacts, STOP 0
  • 1 Signalling output
  • Fit for signal evaluation of outputs of safety magnetic switches
  • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
  • Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks

SRB031MC

  • 1 Signalling output
  • 3 safety contacts, STOP 1
  • Drop-out delay can be set between 0,4 to 1,5 s
  • Fit for signal evaluation of outputs of safety magnetic switches
  • Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
  • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains

SRB202C

  • Two-functions safety monitoring module (double evaluation)
  • 2 Signalling outputs
  • 2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2)
  • Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)

SRB207AN

  • 2 safety contacts, STOP 0
  • 6 Signalling outputs
  • Multi-evaluation of up to 6 safety guards
  • Fit for signal evaluation of outputs of safety magnetic switches
  • Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks

SRB220XV2 / V.2

  • 2 safety contacts, STOP 0; 2 safety contacts, STOP 1
  • Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
  • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains

SRB301HC/R

  • 3 safety contacts, STOP 0
  • 1 Signalling output
  • Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks and Two-hand control panels and Safety mats

SRB301HC/T

  • 3 safety contacts, STOP 0
  • 1 Signalling output
  • Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks and Safety mats